PLUTON presents a new SOTA protection and monitoring system More details
Australia |en
Name of parameter Unit of measurement Value
Installation height above sea level m 100% load up to 1000 m height  
1 % power reduction for each 100 m at more than 1000 m height; 
Max. height 3000 m
Operation temperatures range °C –10 (frost free)…+50: IH
Storage temperatures range °C -40...+60
Upper value of relative humidity at 25 °С % Up to 95 %, non-condensing
Environment - explosion-proof, free from corrosive gases and vapors in insulation destroying concentrations
Placement category - «3» (without insolation and direct influence of atmospheric precipitation)
Acceptable vibration in standard design and optionally Hz

5…150, 
Vibration amplitude 1 mm in a range of 3…15.8 Hz. 
Max. acceleration magnitude 1 G in a range of 15.8…150 Hz.

If required, can be manufactured for more severe mechanical loads conditions