Name of parameter Unit of measurement Value
Three-phase input supply voltage (Uin), with earthed neutral V 380 +10/-15 %
Input voltage frequency Hz 50 ± 2 %
Network connection periodicity times Once per minute or less
Three-phase rated output DC voltage (Uin) V  380 ± 2 %, but no more than Uin
Output voltage rated frequency (Frat) Hz 50 ± 1%
Controlled motors rated power (Рrat) kW from 60 up to 630
Current overload - 1.5 Irat – 1 min per 10 min
Range of output voltage regulation V 0 – Uin
Range of output frequency regulation Hz 0.5 – 60
Efficiency coefficient, minimum - 0.95
Nonlinear network current distortions coefficient, max. % 5
Level protection acc. to IEC 60529 (upon request) - IP 21, IP 43, IP 54
Lifetime, minimum years 15
Mean recovery time, max. min 40
Interference resistance - meets all standards requirements
Overall dimensions of SHIN and VTM at traction power of 110 kW (WхHхD) - 1800×2200×600;
800×2000×600